Click here for enlarged detail
Specifications: Dome skylights shall be factory assembled Model 208 (or 209 double dome) as manufactured by Plasteco, Inc. It shall consist of a Model 100 (or 101 double dome) skylight mounted on a 9' high insulated double wall aluminum curb. The insulation shall be 1-1/2" thick rigid foam. Dome shall be formed of (clear, white translucent or bronze) acrylic to support a uniform 40 psf load. (For Model 209, add: Inner dome shall be formed of (clear or white translucent) acrylic.)
Add Alternate: Fall protection as required by OSHA Regulation 1926.501 "Duty to have fall protection" shall be provided by FallGuard Skylight Screens. These shall be shipped separately and installed prior to the installation of the skylight.
Add Alternate: Plasteco Hail Stone Screens meet the Factory Mutual recommendations for hail screens. The hail screens must resist impact of a 2" diameter hail stone having an impact energy of 22 ft. lbs.
Specifications: Hail stone screen shall consist of a 1" by 1" x .062 galvanized welded wire mesh overlaid on the FallGuard Skylight Screen. |